- 
PMAS Status Window: a mechanical device does not reach a valid end position. 
The corresponding error flag switches to RED.
 
- 
The error condition is a complex function of VME motor controller parameters.
It could be as simple as the timeout of a somewhat worn-out gear, requiring a
longer positioning period than foreseen originally. On the other hand, it
could be a serious mechanical or electronic failure, which might potentially
cause a catastrophic failure of some sort (collision of mechanical stages, 
limit switch overrun, etc.
 
- 
Reset and re-initialize the affected component.
Note: ONLY TO BE DONE BY CAHA STAFF
 
- 
On rike xterm, type (e.g. for collimator focus motor) :
 
rike:colReset
rike:colInit
Verify, that error condition has been solved:
rike:colStatus
- 
Reset/Init scripts are available for the following devices :
 
 Spectrograph Collimator Focus :
  colReset 
  colInit  
  colStatus
 Spectrograph Camera Focus :
  camReset
  camInit
  camStatus
  grotReset
  grotInit
  grotStatus
  foReset
  foInit
  foStatus
 A&G Camera and Calibration Unit exchange mechanism :
  tmtopReset
  tmtopInit
  tmtopStatus
 A&G Camera Filter exchange mechanism:
  agfilReset
  agfilInit
  agfilStatus
  agfocReset
  agfocInit
  agfocStatus
- 
If an error persists despite reset, try :
 
 limevalSet
 immediately following the  reset command.